Standard-probe measured curve
Describes the medium response for the stated probe and test conditions. It is not the surface or core curve of a production workpiece.
Enter measured “distance from quenched end–HRC” data from an end-quench specimen to analyze the 50% martensite hardness crossing and interpolate at a specified distance. The page does not generate a curve from a steel grade.
| # | Distance from Quenched End, mm | Hardness HRC | Remove |
|---|
Data classification
Every curve and conclusion on this site is identified by how the data was obtained.
Describes the medium response for the stated probe and test conditions. It is not the surface or core curve of a production workpiece.
Calculated from a stated model and inputs. It is a prediction, not measured production data.
Comes from internal points in the actual workpiece and is used to assess the real cooling process against post-quench hardness, microstructure and properties.
Explore relevant products and measurement methods, or tell us about your workpiece and current issue.